Forklifts & Attachments

Technical Analysis: Bending Moment, Reach and Residual Capacity in Telescopic Jibs for Forklift Forks

Why a jib's capacity falls with reach, how to size the adjustment pins, and which operating precautions the standards require.

Application & Hydraulic Engineering

INCOFORK Technical Department

October 29, 2026
8 min technical read
Technical Analysis: Bending Moment, Reach and Residual Capacity in Telescopic Jibs for Forklift Forks

Abstract

This study examines the mechanical behavior of a 1,500 mm telescopic jib mounted on a forklift's forks. Capacity is shown to be governed by two independent limits: the jib's own allowable bending moment (with its three adjustment points) and the truck's tipping moment, both functions of reach. It discusses double shear in the locking pins, the influence of the telescoping tube overlap, the swivel hook with safety latch, and the NR-11 and NR-12 requirements for a visible capacity chart and safe lifting.

Keywords: Telescopic jib for forklift, Lifting jib, Bending moment, Reach and capacity, Swivel hook, Capacity chart, NR-11, Big Bag.

1. Introduction: Reach That Standard Forks Do Not Have

Workshops, warehouses and assembly areas often need to lift loads that cannot fit on, or be reached by, the forks: engines to be pulled from a bay, Big Bags to be placed on platforms, molds and dies to be lowered into machines. In those cases the forklift works as a small crane, and the attachment that makes it possible is the jib.

The MJI-1500 M-Series Telescopic Jib has a maximum length of 1,500 mm, three pin-adjustment positions, a forged 360° swivel hook with safety latch, and fork mounting through reinforced channels with clamp knobs and an anchor chain. A 1,550 mm outer tube and 1,512 mm inner tube form the telescopic section.

This study explains what limits the capacity of a jib like this and how reach changes everything.

2. Two Capacities in Series: Jib and Truck

A fork-mounted jib has two independent limits, and the lower one always governs:

Jib structural limit: the bending moment the section can carry. Since moment is force times arm, allowable load drops as the hook moves away from the support. The more extension, the lower the capacity.
Truck stability limit: the tipping moment about the front axle. The hook sits much farther out than the 500 mm reference load center on the plate.

That is why the manufacturer stamps a capacity chart on the structure: each adjustment position has its own maximum capacity. It is also why NR-11 requires capacities to be visible to the operator.

Truck Residual Capacity versus Reach

Holding the plate moment constant: Q' ≈ Q · c₀ / c. Illustrative example: 3,000 kg truck at a 500 mm load center (rated moment 1,500 kgf·m), with the hook at a distance c from the fork face: • c = 900 mm: Q' ≈ 1,667 kg • c = 1,200 mm: Q' ≈ 1,250 kg • c = 1,500 mm: Q' ≈ 1,000 kg These values do not yet subtract the jib's own weight. The jib's adjustment points are not necessarily 900, 1,200 and 1,500 mm: use the chart stamped on the equipment.
MJI-1500 telescopic jib lifting an engine in a workshop
Figure 1: Engine removal with the telescopic jib. The 360° swivel hook prevents twisting the load.

3. Adjustment Pins: Double Shear

The three adjustment points are set by reinforced locking pins that pass through the outer and inner tubes. Each pin works in double shear: two cross-sections resist the shear force.

Shear Stress in the Pin

τ = F / (2 · A) = F / (2 · π · d² / 4) Illustrative example with F = 1,000 kgf (9,810 N) and a Ø20 mm pin: A = 314 mm² per section, 628 mm² in double shear τ = 9,810 / 628 ≈ 15.6 MPa This is far below the shear yield of ordinary structural steel (around 140 to 200 MPa, roughly 0.58 of yield strength), leaving a large margin. The same check must be made for the holes (bearing) and the tube walls.

4. Tube Overlap and Stiffness

In a telescopic jib, bending stiffness is not the same everywhere. Where one tube sits inside the other (overlap), the composite section is stiffer. At full extension the inner tube leaves the sleeve and the overlap is minimal: this is the most critical configuration, both for the greater hook distance and the lower local stiffness.

Hence the design and use recommendation:

Use the shortest position that serves the job.
Avoid abrupt movement and load swing, which amplify dynamic stress.
Keep both tubes clean and lubricated so adjustment is smooth without excessive play.
Re-inspect pins, latches and welds periodically.

5. Swivel Hook, Latch and Fork Mounting

The forged-steel 360° swivel hook follows the load and prevents it from transmitting torque to the jib. The safety latch prevents accidental release of the eye or sling when the load momentarily goes slack.

Fork mounting uses reinforced channels with clamp knobs and an anchor chain. The chain is a second retention point: if friction clamping fails, the jib stays attached to the truck.

Under NR-12, modifications and accessories that change a machine's conditions of use must preserve safety. In practice, lift only with the hook (never tie the load to the jib body), keep people out of the zone beneath the load, and drive with the load low and the mast tilted slightly back.

Golden Rule

Respect the capacity chart stamped on the jib and the truck plate. The lower of the two always governs, after subtracting the jib's weight.

6. Technical Conclusion

The telescopic jib extends the forklift's reach with a compact attachment, but that reach has a mechanical price: capacity falls with the arm, both in the jib structure and in machine stability. Sizing the pins properly, choosing the shortest possible position and respecting the capacity chart are the three measures that turn this attachment into a safe tool.

The MJI-1500 M-Series Telescopic Jib was designed around these principles. To validate the ideal configuration for your operation, contact our engineering team.

Frequently Asked Questions (FAQ)

Engineering technical answers regarding kinematics, hydraulic circuits, NR-12/NR-10 safety and shop floor integration.

1Why does the jib's capacity drop when I extend it?

Because bending moment is force times arm. As the hook moves away from the fork support, the arm grows and the same load produces a larger moment. The structure and the truck have a fixed maximum moment, so allowable load falls proportionally.

2What is the capacity of the MJI-1500 jib?

Capacity depends on the adjustment position and is shown on the capacity chart stamped on the structure. In any case, the working limit is the lower of the jib chart and the truck's residual capacity at that reach.

3Can I travel with the load raised on the jib?

No. To drive the truck, keep the load low and the mast tilted slightly back, at reduced speed. Lifting while the truck moves amplifies swing and brings the tipping limit closer.

4What is the anchor chain for?

It is a secondary retention: if the clamp knobs lose friction, the chain keeps the jib from sliding off the forks.

References & Standards

  1. BRAZIL. Ministry of Labor and Employment. Regulatory Standard No. 11 (NR-11): Transport, Movement, Storage and Handling of Materials. Brasília: MTE.
  2. BRAZIL. Ministry of Labor and Employment. Regulatory Standard No. 12 (NR-12): Safety in Machinery and Equipment. Brasília: MTE.
  3. INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 3691-1: Industrial trucks — Safety requirements and verification. Geneva: ISO.
  4. BEER, F. P.; JOHNSTON JR., E. R. Mechanics of Materials. New York: McGraw-Hill.
  5. GERE, J. M.; GOODNO, B. J. Mechanics of Materials. Boston: Cengage Learning.
MJI-1500 Telescopic Jib (M-Series)

Related Equipment

MJI-1500 Telescopic Jib (M-Series)

Autonomous station with 1.5 HP electro-hydraulic power unit, high-pressure cylinder (100 bar) with deceleration dampening via 3/8" valve, 135° tipping cradle, and full NR-10/NR-12 compliance.